Determinants of point-of-care ultrasound lung sliding amplitude in mechanically ventilated patients

Abstract

Background

Although lung sliding seen by point-of-care ultrasound (POCUS) is known to be affected to varying degrees by different physiologic and pathologic processes, it is typically only reported qualitatively in the critical care setting. Lung sliding amplitude quantitatively expresses the amount of pleural movement seen by POCUS but its determinants in mechanically ventilated patients are largely unknown.

Methods

This was a single-center, prospective, observational pilot study examining 40 hemithoraces in 20 adult patients receiving mechanical ventilation. Each subject had lung sliding amplitude measured in both B-mode and by pulsed wave Doppler at their bilateral lung apices and bases. Differences in lung sliding amplitude were correlated with anatomical location (apex vs base) as well as physiologic parameters including positive end expiratory pressure (PEEP), driving pressure, tidal volume and the ratio of arterial partial pressure of oxygen (PaO2) to fraction of inspired oxygen (FiO2).

Results

POCUS lung sliding amplitude was significantly lower at the lung apex compared to the lung base in both B-mode (3.6 ± 2.0 mm vs 8.6 ± 4.3 mm; p < 0.001) and the pulsed wave Doppler mode (10.3 ± 4.6 cm/s vs 13.9 ± 5.5 cm/s; p < 0.001) corresponding to expected distribution of ventilation to the lung bases. Inter-rater reliability of B-mode measurements was excellent (ICC = 0.91) and distance traversed in B-mode had a significant positive correlation with pleural line velocity (r2 = 0.32; p < 0.001). There was a non-statistically significant trend towards lower lung sliding amplitude for PEEP ≥ 10 cmH2O, as well as for driving pressure ≥ 15 cmH2O in both ultrasound modes.

Conclusion

POCUS lung sliding amplitude was significantly lower at the lung apex than the lung base in mechanically ventilated patients. This was true when using both B-mode and pulsed wave Doppler. Lung sliding amplitude did not correlate with PEEP, driving pressure, tidal volume or PaO2:FiO2 ratio. Our findings suggest that lung sliding amplitude can be quantified in mechanically ventilated patients in a physiologically predictable way and with high inter-rater reliability. A better understanding of POCUS derived lung sliding amplitude and its determinants may aid in the more accurate diagnosis of lung pathologies, including pneumothorax, and could serve as a means of further reducing radiation exposure and improving outcomes in critically ill patients.

Introduction

Point-of-care ultrasonography (POCUS) refers to the acquisition and real-time interpretation of ultrasound imaging data at the patient’s bedside. It is essential to the care of critically ill patients and may help narrow the differential diagnosis of shock and respiratory failure. Daniel Lichtenstein coined the term “lung sliding” to describe the ultrasound appearance of the parietal pleura (lining the inner chest wall) and visceral pleura (lining the surface of the lung) moving against one another during ventilation (Additional file 1: Video S1) [1,2,3]. The lung sliding sign is abolished by pneumothorax [1] due to the near complete reflection of ultrasound waves by free pleural air. However, absent lung sliding may also be seen in other processes affecting lung compliance and regional ventilation including acute respiratory distress syndrome (ARDS), pulmonary fibrosis, chronic obstructive pulmonary disease (COPD) and mechanical ventilation with high levels of positive end expiratory pressure (PEEP) [4,5,6,7]. Absent lung sliding has also been noted at the lung apex relative to the base in mechanically ventilated patients [8].

As in the aforementioned studies, POCUS lung sliding is typically reported qualitatively as being absent or present, but it can be quantified with greater precision. Lung sliding amplitude expresses the amount of pleural movement seen by ultrasound and has been described both in terms of pleural distance travelled in B-mode (mm) [9] and maximum pleural velocity measured by Doppler (cm/s) [10]. However, it has never simultaneously been reported using both B-mode and pulsed wave Doppler in the same study and measurements by these two techniques have never been correlated.

The aim of this pilot study was to identify the determinants affecting POCUS lung sliding amplitude in mechanically ventilated patients. We hypothesized that the lung bases would have increased lung sliding amplitude compared to the lung apices due to preferential distribution of ventilation there and that measurements in B-mode would have a significant positive correlation with the lung sliding velocity measured by pulsed wave Doppler.

Methods

Study design and participants

This was a single center, prospective observational pilot study. The study population consisted of 40 hemithoraces in 20 adult patients admitted to the medical intensive care unit (ICU). Patients were eligible for inclusion if they were receiving mechanical ventilation and > 18 years of age. Patients at the end-of-life or with pathologies precluding accurate assessment of ultrasound lung sliding were excluded. The study protocol was approved by the Lundquist Institute for Biomedical Innovation’s Institutional Review Board and written informed consent was obtained from each subject or their legally authorized representative. Demographic information and physiologic parameters including PEEP, driving pressure, tidal volume and ratio of arterial partial pressure of oxygen to fraction of inspired oxygen (PaO2:FiO2 ratio) were collected.

Point-of-care ultrasound protocol

Pleural ultrasonography (Sonosite X-porte; Fujifilm) was performed using a high frequency linear probe (L38xp; 15-6 MHz). Images were acquired at the lung apex at the second intercostal space in the anterior midclavicular line and the lung base at the lateral midaxillary line, one intercostal space above the hemidiaphragm. The transducer was oriented in the longitudinal plane with the indicator in a cephalad position [2]. Image depth was adjusted individually according to the degree of subcutaneous tissue superficial to the pleural space such that the pleural line was always positioned mid-screen.

In B-mode, a comet-tail artifact, also known as a B-line, or other visible pleural defect was identified by the operator and its maximum displacement over a single breath was measured in millimeters. To replicate real world POCUS conditions, displacement was measured manually without the aid of image analysis software (see Additional file 1: Video S1) and recorded in millimeters. Measurements were performed by two ultrasonographers (one expert and one novice) trained in the use of pleural ultrasound. It should be noted that while pleural defects tend to be easily visible in critically ill patients, it is likely that they occur less frequently in healthy lungs. Pulsed wave Doppler was used to automatically calculate maximum pleural line velocity using a Doppler reading gate of 2 mm in the same ultrasound view as was used for B-mode measurements (Fig. 1). As movement of the pleural line occurs at an angle of 90° to the ultrasound probe, a standardized angle correction of + 60° was used for pleural velocity measurements.

Fig. 1
figure 1

Example measurement of pleural velocity by pulsed wave Doppler. A maximum pleural velocity of 14.5 cm/s (white arrow) was measured with the Doppler reading gate positioned at the pleural line

Statistical analysis

Continuous variables were expressed as means with standard deviations. Differences between groups were assessed using Student’s t-test and Fisher’s exact test. Lung sliding amplitude at the lung apex and lung base was compared using both paired and unpaired t-tests. All reported p values are two-sided. Pearson correlation coefficients were used to express relationships between lung sliding amplitude, pleural line velocity and other recorded physiologic parameters. Inter-rater reliability in B-mode was assessed using intra-class correlation coefficients (ICC).

Results

The median age of patients studied was 56.5 years (interquartile range, 37 to 63) and 60% were male (Table 1). Indications for mechanical ventilation are shown in Table 1. Measurements could not be obtained in some patients due to superiorly displaced hemidiaphragm (n = 5), obese body habitus (n = 2), pneumothorax (n = 1) and large pleural effusion (n = 1). Lung sliding amplitude was successfully measured at the lung apex in 35 patients and at the lung base in 29 patients. Imaging at both the apex and base was obtained in 28 patients (Fig. 2).

Table 1 Patient characteristics
Fig. 2
figure 2

Reasons for excluded measurements at the lung apex vs base

POCUS lung sliding amplitude measured in B-mode was significantly lower at the lung apex compared to the lung base (3.6 ± 2.0 mm vs 8.6 ± 4.3 mm; n = 28; p < 0.001) (Fig. 3). According to categories previously described by Lichtenstein, lung sliding amplitude was further categorized as “normal” if > 10 mm, “significantly reduced” between 4 and 10 mm, “quite abolished” between 1 and 3 mm and “fully abolished” if there was no visible pleural movement (0 mm) [9]. Lung sliding amplitude was more likely to be “quite abolished” at the lung apex (54% apex vs. 3% base; p < 0.001) and less likely to be “normal” (0% apex vs 24% base; p < 0.001). Excluding one patient with undiagnosed pneumothorax, no patients had “fully abolished” lung sliding at any location (Table 2). For B-mode measurements, inter-rater reliability was excellent with an intra-class correlation coefficient (ICC) of 0.91.

Fig. 3
figure 3

Difference in B-mode lung sliding amplitude (mm) between the lung apex and lung base expressed using A paired and B unpaired t-tests

Table 2 Lung sliding amplitude study results

Pleural line velocity measured in the pulsed wave Doppler mode was also significantly lower at the apex compared to the base (10.3 ± 4.6 cm/s vs 13.9 ± 5.5 cm/s; n = 27; p < 0.001). Distance traversed in B-mode had a statistically significant positive correlation with pleural line velocity (r2 = 0.32; p < 0.001) (Fig. 4).

Fig. 4
figure 4

Scatterplot and superimposed best fit line (dashed) showing correlation between lung sliding amplitude measured in B-mode and pleural line velocity measured in the pulsed wave Doppler mode (r2 = 0.32, p < 0.001)

There was a non-statistically significant trend towards lower lung sliding amplitude for PEEP ≥ 10 cmH2O compared with PEEP < 10 cmH2O in both B-mode (5.4 ± 3.3 mm vs 6.3 ± 4.2 mm; p = 0.42) and the pulsed wave Doppler mode (10.1 ± 4.6 cm/s vs 12.4 ± 5.4 cm/s; p = 0.14) (Fig. 5A). There was also a trend toward lower lung sliding amplitude for driving pressure ≥ 15 cmH2O compared with driving pressure < 15 cmH2O in both B-mode (5.3 ± 3.1 mm vs 7.2 ± 4.8 mm; p = 0.06) and the pulsed wave Doppler mode (11.3 ± 5.4 cm/s vs 12.5 ± 5.1 cm/s; p = 0.36) (Fig. 5B). There were no correlations with tidal volume or PaO2:FiO2 ratio.

Fig. 5
figure 5

Scatterplot and superimposed best fit line (dashed) showing correlation between B-mode lung sliding amplitude (mm) and A positive end expiratory pressure (cmH2O) and B driving pressure (cmH2O)

Discussion

POCUS lung sliding amplitude was significantly greater at the lung base compared to the lung apex in mechanically ventilated patients but did not have a statistically significant correlation with other physiologic parameters including PEEP, driving pressure, tidal volume and PaO2:FiO2 ratio. Ventilation is known to be approximately 50% lower at the lung apex compared to the base in normal lungs [11, 12]. Due to the effects of gravity, the cumulative weight of lung parenchyma at the lung base is greater than at the apex, leading to increased pleural pressure and lower resting lung volume. During inspiration, these lower volume, more compliant alveoli experience a greater change in volume compared to those at the apex and, thus, increased ventilation [13, 14]. By studying patients receiving mechanical ventilation with set tidal volumes and semi-upright positions, we were able to utilize expected physiologic differences in regional ventilation between the lung apex and base to demonstrate that subtle differences in lung sliding amplitude can be detected and quantified by pleural ultrasound.

Reduced apical lung sliding amplitude was seen in both B-mode and pulsed wave Doppler. Previous studies examining lung sliding amplitude in mechanically ventilated patients were done using tissue Doppler imaging (TDI) [10] or pulsed wave Doppler [15]. By utilizing B-mode, our study best reflects standard use of lung ultrasound in critically ill patients, such as described by the BLUE-protocol (Bilateral Lung Ultrasound in Emergency) [2]. This remarkably simple measurement has been described before by Lichtenstein [9], but perceived problems with reproducibility and lack of clinical application have limited its widespread use. As expected, B-mode and pulsed wave Doppler measurements had a statistically significant positive correlation. That correlation may be further strengthened in future studies by analyzing the velocity–time integral of the Doppler tracing (i.e., distance traversed = ∫v dt) yielding a Doppler derived measurement of distance that might be more comparable to those obtained in B-mode. Although pulsed wave Doppler measurement has the potential to be less subjective than manual measurement of pleural movement in B-mode, B-mode measurements in our study had excellent inter-rater reliability.

Knowledge of baseline differences in POCUS lung sliding amplitude in critically ill patients will affect the specificity of the abolished lung sliding sign for detecting pneumothorax. For example, in patients with already reduced baseline lung sliding amplitude, false positivity rates for pneumothorax may be increased. Likewise, confirmatory imaging of the lung base in patients with absent apical lung sliding may be a physiologically sound method for confirming the diagnosis of pneumothorax in patients known to already have reduced apical ventilation.

According to prior studies, lung sliding amplitude is reduced by impaired ventilation [4,5,6,7,8]. In our study, this conclusion is further supported by lower lung sliding amplitude at the lung apex relative to the base. Pulmonary pathologies affecting ventilation, such as bacterial pneumonia, tuberculosis or a history of prior pleurodesis are also likely to affect regional lung sliding amplitude. Interestingly, vertical displacement of the pleural line has been shown to correlate with airflow limitation in patients with bronchospasm and could serve to complement horizontal lung sliding amplitude in patients with obstructive lung disease [16]. In light of our growing understanding of its applications, POCUS guided assessment of regional ventilation may represent an untapped well of information in critically ill patients. Further exploring analysis of pleural movement may aid in the ultrasound guided diagnosis of lung pathologies such as lobar pneumonia, COPD and ARDS. It may also help evaluate, or even predict, the effectiveness of therapies aimed at improving regional ventilation, such as prone positioning in ARDS.

We hypothesized that POCUS lung sliding amplitude would correlate with several important factors associated with patient outcomes in the ICU including PEEP, driving pressure, tidal volume and PaO2:FiO2 ratio. In patients with ARDS, increasing PEEP aids alveolar recruitment and improves the overall compliance of the respiratory system but could also cause regional overdistention [17]. Driving pressure (defined as the difference between alveolar pressure at the end of inspiration and PEEP) reflects reduced lung compliance and has been linked to increased mortality in ARDS [18]. In our study, there were trends towards decreased lung sliding amplitude at higher PEEP and driving pressure, but they were not statistically significant. In future studies, a larger population size may better describe this association.

We postulated that lung sliding amplitude would positively correlate with tidal volume, but this was not seen in our study. This was likely because of the lung protective ventilation strategies employed in our ICU with tidal volumes almost always set between 6 and 8 mL/kg of ideal body weight [18]. Because tidal volumes were standardized to predicted lung size for each patient, the distribution of values was small and differences in lung sliding amplitude relative to tidal volume were difficult to detect. Future studies should aim to capture greater differences in lung sliding amplitude at different tidal volumes within the same patient.

Lung sliding amplitude has been evaluated using tissue Doppler [10] and speckle tracking, particularly for the diagnosis of pneumothorax rather than assessment of regional ventilation [19,20,21]. Speckle tracking is a technique routinely used in echocardiography whereby tissue deformation is assessed by analysis of speckle pattern movement in a two-dimensional plane. Measurements by this modality are likely to correlate with the techniques employed in our study, but this hypothesis requires further investigation. Although speckle tracking is an intriguing means of precisely quantifying tissue movement, it requires specialized software not typically available to the POCUS practitioner.

This pilot study had several limitations. First, population size was small. Therefore, our results should be interpreted with caution and treated primarily as hypothesis generating. In the future, a larger number of subjects will be needed to corroborate our findings and better describe correlations between lung sliding amplitude, PEEP and driving pressure. Second, small sample size also affected our ability to study the effect of specific pulmonary pathologies on lung sliding amplitude. Third, because manual measurements of lung sliding amplitude were chosen over software based image analysis to replicate real world POCUS settings, there may have been some subjectivity in image interpretation. However, this limitation was mostly addressed by calculating inter-rater reliability. Also related to ultrasound technique, although automatic angle correction used was used in our Doppler assessments, we are still likely to have underestimated the true velocity of pleural movement occurring perpendicular to the ultrasound probe. Fourth, differences in regional ventilation in this study were assumed based on patient positioning. Future studies correlating lung sliding amplitude to known methods of ventilation quantification will be required. Fifth, the anatomic windows in which ultrasound images were captured were based arbitrarily on previously suggested protocols [2]. In future studies, the locations in which minimal and maximal lung sliding amplitude is observed may provide more accurate insight into the true amount of regional ventilation there. Finally, because our study focused only on patients receiving mechanical ventilation, extrapolation to non-intubated patients is limited.

Conclusion

In this pilot study, POCUS lung sliding amplitude was significantly lower at the lung apex compared to the lung base in mechanically ventilated patients but did not correlate with PEEP, driving pressure, tidal volume or PaO2:FiO2 ratio. This was true when using both B-mode and the pulsed wave Doppler mode. Our findings suggest that lung sliding amplitude can be quantified in a meaningful and physiologically predictable way in mechanically ventilated patients. A better understanding of lung sliding amplitude and its determinants may aid in the more accurate diagnosis of lung pathologies, including pneumothorax, and could serve as a means of further reducing radiation exposure and improving outcomes in critically ill patients.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

ARDS:

Acute respiratory distress syndrome

BLUE:

Bilateral lung ultrasound in emergency

COPD:

Chronic obstructive pulmonary disease

FiO2 :

Fraction of inspired oxygen

ICC:

Intra-class correlation coefficient

ICU:

Intensive care unit

PaO2 :

Arterial partial pressure of oxygen

PEEP:

Positive end expiratory pressure

POCUS:

Point of care ultrasound

TDI:

Tissue Doppler imaging

References

  1. Lichtenstein DA, Menu Y (1995) A bedside ultrasound sign ruling out pneumothorax in the critically ill. Chest 108(5):1345–1348

    Article  CAS  PubMed  Google Scholar 

  2. Lichtenstein DA, Mezière GA (2008) Relevance of lung ultrasound in the diagnosis of acute respiratory failure: the BLUE protocol. Chest 134(1):117–125

    Article  PubMed  PubMed Central  Google Scholar 

  3. Lichtenstein D, Meziere G, Biderman P, Gepner A (2000) The, “lung point”: an ultrasound sign specific to pneumothorax. Intensive Care Med 26(10):1434–1440

    Article  CAS  PubMed  Google Scholar 

  4. Lee F (2016) Lung ultrasound—a primary survey of the acutely dyspneic patient. J Intensive Care 4:57

    Article  PubMed  PubMed Central  Google Scholar 

  5. Rowan K et al (2004) Hand-held thoracic sonography for detecting post-traumatic pneumothoraces: the extended focused assessment with sonography for trauma (EFAST). J Trauma 57:288–295

    Article  PubMed  Google Scholar 

  6. Slater A, Goodwin M, Anderson KE, Gleeson FV (2006) COPD can mimic the appearance of pneumothorax on thoracic ultrasound. Chest 129(3):545–550

    Article  PubMed  Google Scholar 

  7. Markota A et al (2016) Absence of lung sliding is not a reliable sign of pneumothorax in patients with high positive end-expiratory pressure. Am J Emerg Med 34(10):2034–2036

    Article  PubMed  Google Scholar 

  8. Khalil MM, Salem HM, Habib SM (2020) Validity of pleural sliding sign in patients on controlled mechanical ventilation. Egypt J Chest Dis Tuberc 69(3):509–515

    Article  Google Scholar 

  9. Lichtenstein DA (2017) Lung ultrasound (in the critically ill) superior to CT: the example of lung sliding. Korean J Crit Care Med 32(1):1–8

    Article  PubMed  PubMed Central  Google Scholar 

  10. Xiao R, Shao Q, Zhao N, Liu F, Qian KJ (2021) Quantification analysis of pleural line movement for the diagnosis of pneumothorax. World J Clin Cases 9(21):5889–5899

    Article  PubMed  PubMed Central  Google Scholar 

  11. West JB, Luks AM (2020) Mechanics of breathing. In: West's respiratory physiology: the essentials, 11th edn, Wolters Kluwer, pp 116–150

  12. Ball WC, Stewart PB, Newsham LGS, Bates DV (1962) Regional pulmonary function studied with Xenon133. J Clin Invest 41(3):519–531

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  13. Milic-Emili J (2005) Ventilation distribution. In: Hamid Q, Shannon J, Martin J (eds) Physiologic basis of respiratory disease, 1st edn. Hamilton, BC Decker, pp 133–141

    Google Scholar 

  14. Milic-Emili J et al (1966) Regional distribution of inspired gas in the lung. J Appl Physiol 21:749–759

    Article  CAS  PubMed  Google Scholar 

  15. Rose G et al (2017) A novel method of assessing for lung sliding using doppler imaging. Am J Emerg Med 35(11):1738–1742

    Article  PubMed  Google Scholar 

  16. Martins S, Nogue R (2020) Vertical displacement of pleura: a new method for bronchospasm evaluation? Ultrasound J 12(1):42

    Article  PubMed  PubMed Central  Google Scholar 

  17. Grasso S et al (2007) ARDSnet ventilatory protocol and alveolar hyperinflation: role of positive end-expiratory pressure. Am J Respir Crit Care Med 176(8):761–767

    Article  PubMed  Google Scholar 

  18. Acute Respiratory Distress Syndrome Network (2000) Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 342(18):1301–1308

    Article  Google Scholar 

  19. Duclos G et al (2019) Speckle tracking quantification of lung sliding for the diagnosis of pneumothorax: a multicentric observational study. Intensive Care Med 45(9):1212–1218

    Article  CAS  PubMed  Google Scholar 

  20. Fissore E (2021) Pneumothorax diagnosis with lung sliding quantification by speckle tracking: a prospective multicentric observational study. Am J Emerg Med 49:14–17

    Article  PubMed  Google Scholar 

  21. Duclos G, Muller L, Leone M, Zieleskiewicz L (2019) A picture’s worth a thousand words: speckle tracking for quantification and assessment of lung sliding. Intensive Care Med 45(1):101–102

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

No funding sources to declare.

Author information

Authors and Affiliations

Authors

Contributions

All authors (DB, CC, JN and CL) participated in data collection, data analysis and manuscript preparation. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Charles W. Lanks.

Ethics declarations

Ethics approval and consent to participate

The study protocol was approved by the Lundquist Institute for Biomedical Innovation’s Institutional Review Board and written informed consent was obtained from each subject or their legally authorized representative.

Consent for publication

Not applicable.

Competing interests

No competing interest to disclose.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1: Video S1. Example measurement of lung sliding amplitude in B-mode. A B-line is tracked over the course of a mechanical breathwith horizontal distance traversed in this example measured to be approximately 7 mm.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Briganti, D.N., Choi, C.E., Nguyen, J. et al. Determinants of point-of-care ultrasound lung sliding amplitude in mechanically ventilated patients. Ultrasound J 15, 25 (2023). https://doi.org/10.1186/s13089-023-00326-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13089-023-00326-5

Keywords