Skip to main content
  • Letter to the Editor
  • Open access
  • Published:

Clinical relevance of a multiorgan focused clinical ultrasound in internal medicine


Dear Editor,

In December 2021, our group published in JAMA Network Open the main result of a randomized controlled trial (RCT) assessing the impact of a multiorgan focused clinical ultrasound (FCU) on the length of hospital stay of patients admitted to internal medicine units with cardiopulmonary presentations. FCU involved cardiac, lung and proximal lower limb veins ultrasound performed in the first 24 h of admission. We did not find a statistically significant difference in the hospital length of stay between groups [1]. Early this year, Luigi Vetrugno et al. published a letter to the editor analyzing whether based on our results, FCU would be considered a positive, neutral, or harmful tool [2]. The aim of our letter is to provide further information for a comprehensive answer to that question.

In addition to the outcomes reported, we assessed the effect of FCU on the clinical decision-making process using a clinical assessment form before and immediately after the FCU findings were revealed to the treating team [3]. This information was gathered only from patients allocated to the intervention group (n = 124). After knowing the FCU findings, the treating physician changed their assessment of the patient's hemodynamic state in 63 (51%) participants and modified the primary diagnosis in 34 (27%) and was able to rule out the second most likely diagnosis in 29 (23%) of them. Findings suggesting left ventricle (LV) diastolic failure with preserved systolic function was found in 30 (24%) participants. The proportion of findings that were previously unknown by the treating team are illustrated in Fig. 1. After FCU, the treating team: added or removed pharmacological treatment in 30 (24%) participants; modified the requirement of imaging tests in 64 (52%) and blood tests in 57 (46%) of the participants; and changed the option of consulting another specialist in 21 (17%) of them. Details on the direction of the management changes (“step-down” versus “step-up”) are summarized in Fig. 2.

Fig. 1
figure 1

Proportion of previously unknown ultrasound abnormalities. In green (new diagnosis), the proportion of patients in whom FCU identified a pathology that it was unknown and not suspected by the treating team. In gray, the FCU abnormal findings that were already known to the clinical team. APO acute pulmonary oedema, DVT deep vein thrombosis, LV left ventricle

Fig. 2
figure 2

Change in management after FCU. The proportion of participants in the intervention group who had a modification in the medical plan after FCU. The left side of the graph (red) illustrates the percentage of participants who had a step-down in management after FCU and the right side (green) who had a step-up. “Step-down” implies that medical therapies were stopped or referrals, imaging tests, and pathology tests were not requested compared to the pre-FCU plan. “Step up” infers the opposite. CT computed tomography, MRI magnetic resonance imaging, BNP brain natriuretic peptide

Overall, we agree with Vetrugno et al. [2] that the main utility of FCU is to improve physicians’ clinical performance, which is comparable to the role of the stethoscope or the pulmonary artery catheter. Therefore, we adhere to the call to be cautious in defining the clinical relevance of FCU based solely on its impact (or not) on clinical outcomes. In our study, despite not reducing the length of hospital stay, FCU assisted with the clinician’s diagnostic formulation, the decision of requesting further investigations and commencing or ceasing medical therapies.

Its role in supporting the clinical decision-making process could be considered sufficient to call FCU a positive tool. However, we genuinely believe that FCU can potentially lead to earlier hospital discharge in some specific clinical scenarios. Furthermore, this effect is probably enhanced when FCU is used repeatedly during the hospital stay to guide therapy and not merely for the initial diagnostic assessment.

Availability of data and materials

Deidentified data available for researchers whose proposed use of the data has been approved and after a proposal and signed data access agreement.

References

  1. Cid-Serra X, Royse A, Canty D, Johnson DF, Maier AB, Fazio T et al (2021) Effect of a multiorgan focused clinical ultrasonography on length of stay in patients admitted with a cardiopulmonary diagnosis: a randomized clinical trial. JAMA Netw Open 4(12):e2138228

    Article  Google Scholar 

  2. Vetrugno L, Ventin M, Maggiore SM (2022) Focus clinical ultrasonography: again competency differs from the patient outcome. Ultrasound J 14(1):8

    Article  Google Scholar 

  3. Cid X, Canty D, Royse A, Maier AB, Johnson D, El-Ansary D et al (2020) Impact of point-of-care ultrasound on the hospital length of stay for internal medicine inpatients with cardiopulmonary diagnosis at admission: study protocol of a randomized controlled trial-the IMFCU-1 (internal medicine focused clinical ultrasound) study. Trials 21(1):53

    Article  Google Scholar 

Download references

Acknowledgements

None.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

XCS study design, data collection, data analysis and manuscript writing. AR, DC and CR study design, data analysis and revision of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Ximena Cid-Serra.

Ethics declarations

Ethics approval consent to participate

Protocol approved by The Melbourne Health Research Ethics Committee on the 27 June 2018 (protocol reference 2018.200).

Consent for publication

Written informed consent was provided by all the participants accepting participation in the study and de-identified data publication.

Competing interests

The authors do not have competing interests to declare.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visithttp://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Cid-Serra, X., Royse, A., Canty, D. et al. Clinical relevance of a multiorgan focused clinical ultrasound in internal medicine. Ultrasound J 14, 16 (2022). https://doi.org/10.1186/s13089-022-00269-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13089-022-00269-3