- Meeting abstract
- Open Access
- Published:
Evaluation of a novel simulation method of teaching B-lines: hand ultrasound with a wet foam dressing material
Critical Ultrasound Journal volume 7, Article number: A30 (2015)
Background
Lung ultrasound simulations for pathologic conditions are not readily available for bedside teaching. Recently hand ultrasound was introduced as a new model of simulating lung ultrasound including normal lung sliding, stratosphere sign, and lung point. However no effective method of teaching B-lines has been reported.
Objective
The aim of this study was to evaluate effectiveness of a novel mode of teaching B-lines made by using hand ultrasound with a wet foam dressing material simulating a wet lung.
Patients and methods
All subjects enrolled were medical school students who were novice for lung ultrasound. All subjects attended a 20-mintutes lecture about lung ultrasound using simulated video clips of A-lines, B-lines, and lung sliding for 20 minutes and 20-minutes post-test was given. A post-test were composed of questions on the choice between A-lines and B-lines and the presence of lung sliding using randomly mixed 20 real and 20 simulated video clips using hand ultrasound with or without a wet foam dressing materials. At the end of the post-test, the correct answer was revealed and discussed. Paired t test was used to compare the each score of A-lines, B-lines, and lung sliding between the real images and simulated models.
Results
There were 56 male and 20 female with mean age of 25.1±2.8. The mean of the total score was 51.9±4.9 for the real video clips and 52.3±5.0 for the simulated models (P=0.485). The mean of the score for correct answers between A-lines and B-lines was 17.5±2.6 for the real video clips and 17.0±2.0 for the simulated clips (P=0.0961) The mean of the score for lung sliding was 16.0±2.7 in real image and 17.6±2.6 in simulated images (P<0.001).
Conclusion
The novel B-line teaching model by using a hand ultrasound with a wet foam dressing material was readily available and effective method to simulate pulmonary interstitial syndrome.
References
Shokoohi H, Boniface K: Hand Ultrasound: A High-fidelity Simulation of Lung Sliding. Acad Emerg Med 2012, 19(9):E1079–83. 10.1111/j.1553-2712.2012.01431.x
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0), which permits use, duplication, adaptation, distribution, and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Cho, Y., Lee, K., Ahn, J. et al. Evaluation of a novel simulation method of teaching B-lines: hand ultrasound with a wet foam dressing material. Crit Ultrasound J 7 (Suppl 1), A30 (2015). https://doi.org/10.1186/2036-7902-7-S1-A30
Published:
DOI: https://doi.org/10.1186/2036-7902-7-S1-A30
Keywords
- Simulated Model
- Interventional Radiology
- Correct Answer
- Simulation Method
- Video Clip